A five-year study (2008–2012) assessed air quality around the Logbaba thermal power plant in Douala, Cameroon, through numerical modeling of SO₂, NOₓ, CO, and PM₂.₅ dispersion using the AERMOD model. Validation with wind rose data and NOAA in-situ measurements indicated that NOₓ was the most significant pollutant at the plant’s outlet, reaching 259.1% of its relative concentration over one hour and 51.0% over one year. Even beyond 330 meters—where residential areas begin—NOₓ remained a major concern, maintaining a 100% relative pollution rate. The study concluded that pollution levels, particularly for NOₓ, exceed the World Health Organization’s air quality guidelines, making NOₓ the most critical pollutant affecting nearby residents.
Une étude quinquennale (2008-2012) a évalué la qualité de l’air autour de la centrale thermique de Logbaba à Douala, au Cameroun, grâce à une modélisation numérique de la dispersion de SO₂, NOₓ, CO et PM₂.₅ à l’aide du modèle AERMOD. La validation avec les données de la rose des vents et les mesures in situ de la NOAA a indiqué que le NOₓ était le polluant le plus important à la sortie de la centrale, atteignant 259,1 % de sa concentration relative sur une heure et 51,0 % sur un an. Même au-delà de 330 mètres, là où commencent les zones résidentielles, le NOₓ est resté une préoccupation majeure, conservant un taux de pollution relative de 100 %. L’étude a conclu que les niveaux de pollution, en particulier pour le NOₓ, dépassent les recommandations de l’Organisation mondiale de la santé en matière de qualité de l’air, faisant du NOₓ le polluant le plus critique pour les résidents à proximité.